English
Home ProductsPen PH meter, ORP meter, TDS meter, Conductivity meter

PHS-98108 Pen PH meters with auto temperature calibration

PHS-98108 Pen PH meters with auto temperature calibration

  • PHS-98108 Pen PH meters with auto temperature calibration
PHS-98108 Pen PH meters with auto temperature calibration
Product Details:
Place of Origin: China
Model Number: PHS-98108
Payment & Shipping Terms:
Minimum Order Quantity: 1pc of PHS-98108 hanna Pen PH meters with ATC
Price: USD1 of PHS-98108 hanna Pen PH meters with ATC
Packaging Details: 100pcs / carton of hanna PHS-98108 Pen PH meters with ATC
Delivery Time: 10 days of PHS-98108 hannaPen PH meters with ATC
Payment Terms: TT of PHS-98108 hanna Pen PH meters with ATC
Supply Ability: 5000000pcs of PHS-98108 hanna Pen PH meters with ATC
Contact Now
Detailed Product Description

PHS-98108 Pen PH meters with ATC

 

SPECIFICATIONS

 

Technical data:

Measuring range: 0.00~14.00pH

Resolution: 0.1pH

Accuracy: ±0.1pH or 0.05pH

Calibration: manual, 2 points

ATC:   5-60 

Power: 4×1.5v alkaline (AG13)

Auto shut-off: Approx. 4minutes

Dimension: 175×41×23mm

Weight: 90g

PHS-98108 Pen PH meters with auto temperature calibration 0

OPERATION

• Remove the protective cap. Don't be worry if white crystals appear around the probe head. This is normal with pH electrodes and they dissolve when rinsed with water.

• Turn the meter on by sliding switch on the top.

• Immerse into solution up to the max immersion level.

• Stir gently and wait until the display stabilizes.

• After use, switch off pH meter, use the water clean the electrode and replace the protective cap.

• Large fluctuations in readings could be due to lack of calibration, dry electrode or rundown batteries.

PHS-98108 Pen PH meters with auto temperature calibration 1

 

PHS-98108 Pen PH meters with auto temperature calibration 2  PHS-98108 Pen PH meters with auto temperature calibration 3

 

PHS-98108 Pen PH meters with auto temperature calibration 4

PHS-98108 Pen PH meters with auto temperature calibration 5

CALIBRATION

• Immerse the tester up to the maximum immersion level in pH 6.86 buffer solution

• Allow the reading to stabilize and using a small screwdriver adjust the calibration trimmer to read 6.86

Calibration is now complete.

ALWAYS USE FRESH BUFFERS FOR CALIBRATION.

 

BATTERY REPLACEMENT

When the meter cannot be switched on or the display fades, pull out the battery compartment and replace all three 1.5V batteries, while paying attention to their polarity. Batteries should only be replaced in a safe area using the battery type specified in  instruction manual.(1.5 Alklaine or AG13)

PHS-98108 Pen PH meters with auto temperature calibration 6

HANNA HI98108 pHep PEN PH meter PH tester

Contact Details
Please input your companyname!
Send your inquiry directly to us (0 / 3000)

Other Products
Request A Quote

| Sitemap

Privacy Policy | China Pen PH meter, ORP meter, TDS meter, Conductivity meter Supplier. Copyright © 2026 Please input your companyname!. All Rights Reserved. Developed by ECER